NSN 5945-00-034-2317 Repair Services
Electromagnetic Relay Overhaul, Repair, and Maintenance
MPN: 135-1049, FC6-288
Pricing and Lead Time Quote
Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5945-00-034-2317 electromagnetic relayFAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.
We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.
NSN 5945-00-034-2317 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.
Repairability and Datasheet
NSN 5945-00-034-2317 can be offered in repaired, serviceable, overhauled, or inspected conditions.National Stock Number (NSN) | 5945-00-034-2317 |
Categorization | Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v |
Repairability Code | N |
Approximate Weight | 0.1lb |
Thread Class | 2a single mounting facility |
Overall Length | 2.000 inches |
Center To Center Distance Between Mounting Facilities Parallel To Length | 1.557 inches single mounting facility and 1.567 inches single mounting facility |
Overall Height | 1.940 inches |
Overall Width | 1.320 inches |
Environmental Protection | Hermetic |
Fragility Factor | Moderately rugged |
Contact Material | Silver |
Contact Surface Treatment | Gold |
Winding Quantity | 1 |
Purpose For Which Designed | General |
Coil Quantity | 1 |
Winding Dc Resistance Rating | 200.0 ohms single winding |
Duty Type | Continuous |
Arc Quenching Method | Air |
Mounting Facility Type And Quantity | 2 threaded stud single mounting facility |
Storage Type | General purpose warehouse |
Cubic Measure | 5.123 cubic inches |
Thready Qty Per Inch (tpi) | 32 single mounting facility |
Thread Size | 0.138 inches single mounting facility |
Mounting Facility Pattern | In-line single mounting facility |
Nonpile-up Main Contact Arrangement | 6 pole, double throw, one position momentary |
Operating Voltage Rating And Type At Specificationified Temp | 26.5 volts dc 25 degrees celsius single winding |
Main Contact Load Current Rating At Maximum Rated Voltage | 2.0 amperes dc resistive load |
Main Contact Maximum Voltage Rating In Volts | 28.0 dc |
Precious Material And Location | Conacts silver and contact surfaces gold |
Precious Material | Silver and gold |
Thread Series Designator | Unc single mounting facility |
Terminal Type And Quantity | 20 wire hook all functions |
Part Numbers
Part Number | Company | RNAAC (Repair Depot) |
---|---|---|
135-1049 | STRUTHERS-DUNN INC | TX - DLA LAND AND MARITIME |
FC6-288 | STRUTHERS-DUNN INC | TX - DLA LAND AND MARITIME |
FC6-288 | TE CONNECTIVITY CORPORATION | ZZ - USA |
FC6-288 | STRUTHERS-DUNN LLC | ZZ - USA |