NSN 5945-00-027-4278 Repair Services
Electromagnetic Relay Overhaul, Repair, and Maintenance
MPN: TFMD0CC, KCP11-2500, 1215G2-5, W88CPX16, KCP11D2500
Pricing and Lead Time Quote
Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5945-00-027-4278 electromagnetic relayFAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.
We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.
NSN 5945-00-027-4278 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.
Repairability and Datasheet
NSN 5945-00-027-4278 can be offered in repaired, serviceable, overhauled, or inspected conditions.National Stock Number (NSN) | 5945-00-027-4278 |
Categorization | Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v |
Repairability Code | |
Approximate Weight | 0.0lb |
Overall Length | 1.406 inches |
Overall Height | 2.000 inches |
Overall Width | 1.406 inches |
Case Material | Plastic |
Environmental Protection | Dustproof |
Fragility Factor | Moderately rugged |
Contact Material | Silver |
Contact Surface Treatment | Gold flash |
Winding Quantity | 1 |
Purpose For Which Designed | General |
Coil Quantity | 1 |
Winding Dc Resistance Rating | 2.5 kilohms single winding |
Duty Type | Continuous |
Arc Quenching Method | Air |
Mounting Facility Type And Quantity | 1 plug-in terminal single mounting facility |
Storage Type | General purpose warehouse |
Nonpile-up Main Contact Arrangement | 2 pole, double throw, one position momentary |
Operating Current Rating And Type | 10.0 milliamperes dc single winding |
Time Delay | 0.02 seconds fixed operate time |
Main Contact Load Current Rating At Maximum Rated Voltage | 2.0 amperes ac resistive load and 2.0 amperes dc resistive load |
Main Contact Maximum Voltage Rating In Volts | 115.0 ac and 30.0 dc |
Energizing Element Power Rating | 250.0 milliwatts |
Precious Material And Location | Contacts silver and contact surfaces gold |
Precious Material | Silver and gold |
Terminal Type And Quantity | 1 standard tube base all functions |
Part Numbers
Part Number | Company | RNAAC (Repair Depot) |
---|---|---|
TFMD0CC | ALLIED CONTROLS, INC. | 48 - FEDERAL AVIATION ADMINISTRATION |
KCP11-2500 | TE CONNECTIVITY CORPORATION | TX - DLA LAND AND MARITIME |
1215G2-5 | GUARDIAN ELECTRIC MANUFACTURING CO. | TX - DLA LAND AND MARITIME |
W88CPX16 | SE RELAYS LLC MAGNECRAFT | TX - DLA LAND AND MARITIME |
KCP11D2500 | TE CONNECTIVITY CORPORATION | TX - DLA LAND AND MARITIME |