NSN 6110-01-159-3684 Repair Services
Motor Starter Overhaul, Repair, and Maintenance
MPN: 6956ED307A2, 6956ED201A2
Pricing and Lead Time Quote
Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 6110-01-159-3684 motor starterFAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.
We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.
NSN 6110-01-159-3684 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.
Repairability and Datasheet
NSN 6110-01-159-3684 can be offered in repaired, serviceable, overhauled, or inspected conditions.National Stock Number (NSN) | 6110-01-159-3684 |
Categorization | Electrical machines and apparatus parts |
Repairability Code | |
Approximate Weight | 0.0lb |
Speed Adjustments | 0 to full speed |
Hazardous Locations/environmental Protection | Dripproof |
Overall Length | 17.187 inches |
Overall Height | 8.437 inches |
Overall Width | 15.125 inches |
Ac Voltage Rating | 440.0 volts |
Frequency Rating | 60.0 hertz |
Actuation Method | Magnetic |
Performance Type | Semiautomatic |
Fuse Accommodation Quantity | 4 |
Size Designator | 2 |
Duty Cycle | Continuous |
Mounting Configuration | Four 17/32 in. Diameter holes; rectangular pattern; on 11-1/2 in. By 15-3/8 in. Centers |
Operating Voltage Characteristic | Full |
Actuator Voltage | 440.0 ac |
Fuse Current Rating In Amps | 10.0 |
Load Protection Type | Undervoltage |
Ambient Temp | 50.0 degrees celsius |
Inclosure Feature | Dripproof |
National Electrical Manufacturers Association Standards Design | Designed per nema std |
Amp Size Rating | 45.0 |
Switch Functional Positions | Start |
Control Type | Local |
Features Provided | Circuit protection fuse |
Phase | Three |
Frequency In Hertz | 60.0 |
Part Numbers
Part Number | Company | RNAAC (Repair Depot) |
---|---|---|
6956ED307A2 | DRS POWER & CONTROL TECHNOLOGIES, | CX - DLA AVIATION |
6956ED201A2 | DRS POWER & CONTROL TECHNOLOGIES, | CX - DLA AVIATION |