NSN 5925-00-279-6742 Repair Services
Circuit Breaker Overhaul, Repair, and Maintenance
MPN: DKN40
Pricing and Lead Time Quote
Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-279-6742 circuit breakerFAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.
We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.
NSN 5925-00-279-6742 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.
Repairability and Datasheet
NSN 5925-00-279-6742 can be offered in repaired, serviceable, overhauled, or inspected conditions.National Stock Number (NSN) | 5925-00-279-6742 |
Categorization | Automatic circuit breakers, for a voltage not exceeding 1,000 v |
Repairability Code |
M
Medium demand velocity items (consumables) |
Approximate Weight | 0.0lb |
Pole Quantity | 2 |
Features Provided | Adjustable trip release |
Maximum Continuous Load Current Rating Per Pole | 200.0 amperes dc all locations |
Operating Voltage Type And Rating Per Pole In Volts | 250.0 dc all locations |
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 25000.0 dc all locations |
Circuit Protection Type | Overcurrent second location |
Trip Release Method | Magnetic all locations |
Trip Release Characteristic | Time delay all locations |
Reset Method | Manual |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull and 1 rotary |
Actuator Function | Trip w/separate reset |
Auxiliary Switch Function And Quantity | 1 control |
Adjustable Trip Setting Current Range Per Pole In Amps | +200.0/+400.0 dc all locations |
Terminal Type And Quantity | 4 bus bar |
Reference Number Differentiating Characteristics | As differentiated by pole quantity; continuous load current rating per pole; operating voltage type and rating per pole in volts; adjustable trip setting current range per pole in amps |
Part Numbers
Part Number | Company | RNAAC (Repair Depot) |
---|---|---|
DKN40 | WESTINGHOUSE ELECTRIC CORP | XX - |