NSN 5925-00-261-7924 Repair Services

Circuit Breaker Overhaul, Repair, and Maintenance

MPN: JA2-B3-A-5-P

Pricing and Lead Time Quote

Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-261-7924 circuit breaker
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925002617924


Privacy | Terms

AS9120B:2015 ISO 9001 Audited and Certified

FAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.

We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.

NSN 5925-00-261-7924 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.

Repairability and Datasheet

NSN 5925-00-261-7924 can be offered in repaired, serviceable, overhauled, or inspected conditions.
National Stock Number (NSN) 5925-00-261-7924
Categorization Automatic circuit breakers, for a voltage not exceeding 1,000 v
Repairability Code

Approximate Weight 0.1lb
Body Style Multipole-multiple actuator type
Body Length Between 1.985 inches and 2.015 inches
Body Width Between 1.468 inches and 1.532 inches
Case Material Plastic
Center To Center Distance Between Terminals Parallel To Length Between 1.555 inches and 1.565 inches
Center To Center Distance Between Terminals Parallel To Width Between 0.745 inches and 0.755 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length Between 1.655 inches and 1.665 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width Between 0.745 inches and 0.755 inches
Fragility Factor Moderately rugged
Boss Height Between 0.125 inches and 0.135 inches
Mounting Surface To Terminal End Distance Between 1.835 inches and 1.845 inches
Pole Quantity 2
Arc Quenching Method Magnetic blowout
Mounting Facility Type And Quantity 4 threaded hole
Storage Type General purpose warehouse
Thready Qty Per Inch (tpi) 32
Maximum Continuous Load Current Rating Per Pole 5.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts 65.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 1000.0 dc all locations
Circuit Protection Type Overcurrent all locations
Trip Release Method Magnetic-hydraulic all locations
Trip Release Characteristic Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 125.0 all locations
Reset Method Manual
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 2 toggle
Actuator Function Trip-reset
Actuator Position Designation At each pole
External Actuator Linkage Arrangement One and two linked
Internal Trip Release Configuration Series trip all locations
Thread Size 0.138 inches
Inclosure Protection Type For Which Designed Dustproof and fungus resistant
Thread Series Designator Unc
Terminal Type And Quantity 4 tab, solder lug

Part Numbers

Part Number Company RNAAC (Repair Depot)
JA2-B3-A-5-P EATON CORP TX - DLA LAND AND MARITIME