NSN 5925-00-241-9772 Repair Services

Circuit Breaker Overhaul, Repair, and Maintenance

MPN: E1441-10, 8731K3, 9033703

Pricing and Lead Time Quote

Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-241-9772 circuit breaker
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925002419772


Privacy | Terms

AS9120B:2015 ISO 9001 Audited and Certified

FAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.

We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.

NSN 5925-00-241-9772 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.

Repairability and Datasheet

NSN 5925-00-241-9772 can be offered in repaired, serviceable, overhauled, or inspected conditions.
National Stock Number (NSN) 5925-00-241-9772
Categorization Automatic circuit breakers, for a voltage not exceeding 1,000 v
Repairability Code

Approximate Weight 0.0lb
Overall Length 2.875 inches
Overall Height 2.188 inches
Overall Width 0.750 inches
Case Material Plastic
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length 1.812 inches
Pole Quantity 1
Arc Quenching Method Air
Mounting Facility Type And Quantity 2 threaded hole
Thready Qty Per Inch (tpi) 32
Maximum Continuous Load Current Rating Per Pole 10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 1500.0 dc single location
Circuit Protection Type Overcurrent single location
Trip Release Method Thermal single location
Trip Release Characteristic Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 130.0 single location
Reset Method Manual
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 1 toggle
Actuator Function Trip-reset
Actuator Position Designation At pole one
Internal Trip Release Configuration Series trip single location
Thread Size 0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current 10.000 at 200 pct single location and 100.000 at 200 pct single location
Trip Release Ambient Tempurature Rating 25.0 degrees celsius single location
Thread Series Designator Unc
Terminal Type And Quantity 2 screw

Part Numbers

Part Number Company RNAAC (Repair Depot)
E1441-10 NAVAIR AND NAVSEA MANAGED TX - DLA LAND AND MARITIME
8731K3 SAFRAN ELECTRICAL & POWER USA, LLC TX - DLA LAND AND MARITIME
9033703 NAVAIR AND NAVSEA MANAGED TX - DLA LAND AND MARITIME
8731K3 EATON CORP TX - DLA LAND AND MARITIME