NSN 5925-00-191-9757 Repair Services

Circuit Breaker Overhaul, Repair, and Maintenance

MPN: 2812213, 13-0550-150, 109-215-101

Pricing and Lead Time Quote

Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-191-9757 circuit breaker
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925001919757


Privacy | Terms

AS9120B:2015 ISO 9001 Audited and Certified

FAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.

We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.

NSN 5925-00-191-9757 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.

Repairability and Datasheet

NSN 5925-00-191-9757 can be offered in repaired, serviceable, overhauled, or inspected conditions.
National Stock Number (NSN) 5925-00-191-9757
Categorization Automatic circuit breakers, for a voltage not exceeding 1,000 v
Repairability Code N

Approximate Weight 0.1lb
Body Style Single pole type
Bushing Length 0.375 inches
Body Length 1.375 inches
Body Width 0.687 inches
Case Material Plastic
Center To Center Distance Between Terminals Parallel To Length 1.020 inches
Mounting Surface To Terminal End Distance 2.035 inches
Pole Quantity 1
Mounting Facility Type And Quantity 1 threaded bushing w/panel seal
Thready Qty Per Inch (tpi) 24
Maximum Continuous Load Current Rating Per Pole 15.0 amperes ac single location and 15.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts 250.0 ac single location and 32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 3000.0 ac single location and 5000.0 dc single location
Circuit Protection Type Overcurrent single location
Trip Release Method Thermal single location
Trip Release Characteristic Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 135.0 single location
Ultimate Trip Time Per Pole In Seconds 40.000 single location and 200.000 single location
Reset Method Manual
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 1 push-pull
Actuator Function Trip-reset
Actuator Position Designation At pole one
Internal Trip Release Configuration Series trip single location
Thread Size 0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current 9.000 at 200 pct single location and 25.000 at 200 pct single location and 2.500 at 300 pct single location and 5.500 at 300 pct single location
Inclosure Protection Type For Which Designed Shockproof and vibrationproof
Trip Release Ambient Tempurature Rating 25.0 degrees celsius single location
Frequency In Hertz 400.0 single location
Thread Series Designator Unf
Terminal Type And Quantity 2 screw

Part Numbers

Part Number Company RNAAC (Repair Depot)
2812213 NAVAIR AND NAVSEA MANAGED HD - NAVAL INVENTORY CONTROL POINT
13-0550-150 COMPUNETICS INC. HD - NAVAL INVENTORY CONTROL POINT
109-215-101 WOOD ELECTRIC OPERATIONS POTTER AND HD - NAVAL INVENTORY CONTROL POINT