NSN 5925-00-185-4020 Repair Services

Circuit Breaker Overhaul, Repair, and Maintenance

MPN: XAM33M6-20, 260-1014-050, APL111-1-62-203-M, M55629/5-101, MIL-C-55629/5, 7727721P009, APL111-55629-5-101, 632237-136, AM333MG6-20-250-4-60, AM333MG3-20-250AC60-4, AM333MG6-20-250VAC60C4, 220-220-101, AM3-Z29-101, AM333-20-125-4-60

Pricing and Lead Time Quote

Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-185-4020 circuit breaker
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925001854020


Privacy | Terms

AS9120B:2015 ISO 9001 Audited and Certified

FAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.

We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.

NSN 5925-00-185-4020 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.

Repairability and Datasheet

NSN 5925-00-185-4020 can be offered in repaired, serviceable, overhauled, or inspected conditions.
National Stock Number (NSN) 5925-00-185-4020
Categorization Automatic circuit breakers, for a voltage not exceeding 1,000 v
Repairability Code Z

This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.

Approximate Weight 0.3lb
Thread Pitch Diameters +0.1177/+0.1214 inches
Body Style Multipole-multiple actuator type
Body Length Between 2.490 inches and 2.510 inches
Body Width Between 2.240 inches and 2.260 inches
Case Material Plastic
Center To Center Distance Between Terminals Parallel To Length Between 1.928 inches and 1.948 inches
Center To Center Distance Between Terminals Parallel To Width Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length Between 2.052 inches and 2.072 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width Between 0.740 inches and 0.760 inches
Fragility Factor Moderately rugged
Boss Height Between 0.130 inches and 0.150 inches
Mounting Surface To Terminal End Distance Between 2.689 inches and 2.813 inches
Pole Quantity 3
Arc Quenching Method Magnetic blowout
Mounting Facility Type And Quantity 6 threaded hole
Storage Type General purpose warehouse
Thready Qty Per Inch (tpi) 32
Maximum Continuous Load Current Rating Per Pole 20.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts 240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 1000.0 ac all locations
Circuit Protection Type Overcurrent all locations
Trip Release Method Magnetic all locations
Trip Release Characteristic Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 115.0 all locations
Reset Method Manual
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 3 toggle
Actuator Function Trip-reset
Actuator Position Designation At each pole
External Actuator Linkage Arrangement One, two, and three linked
Internal Trip Release Configuration Series trip all locations
Thread Size 0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current 2.200 at 200 pct all locations and 20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed Fungus resistant and moisture resistant
Frequency In Hertz 60.0 all locations
Test Data Document 81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator Unc
Terminal Type And Quantity 6 threaded stud
Specification Data 81349-mil-c-55629/5 government specification

Part Numbers

Part Number Company RNAAC (Repair Depot)
XAM33M6-20 EATON CORP TU - DLA LOGISTICS INFORMATION SERVICE
260-1014-050 ROCKWELL COLLINS, INC. TX - DLA LAND AND MARITIME
APL111-1-62-203-M SENSATA TECHNOLOGIES MARYLAND, INC TX - DLA LAND AND MARITIME
M55629/5-101 MILITARY SPECIFICATIONS TX - DLA LAND AND MARITIME
MIL-C-55629/5 MILITARY SPECIFICATIONS TX - DLA LAND AND MARITIME
7727721P009 LOCKHEED MARTIN CORPORATION TX - DLA LAND AND MARITIME
APL111-55629-5-101 SENSATA TECHNOLOGIES MARYLAND, INC TX - DLA LAND AND MARITIME
7727721P009 GENERAL ELECTRIC COMPANY TX - DLA LAND AND MARITIME
632237-136 LOCKHEED MARTIN CORPORATION TX - DLA LAND AND MARITIME
AM333MG6-20-250-4-60 EATON CORP TX - DLA LAND AND MARITIME
AM333MG3-20-250AC60-4 EATON CORP TX - DLA LAND AND MARITIME
AM333MG6-20-250VAC60C4 EATON CORP TX - DLA LAND AND MARITIME
220-220-101 WOOD ELECTRIC OPERATIONS POTTER AND TX - DLA LAND AND MARITIME
AM3-Z29-101 EATON CORP ZZ - USA
AM333-20-125-4-60 EATON CORP ZZ - USA