NSN 5925-00-163-2071 Repair Services

Circuit Breaker Overhaul, Repair, and Maintenance

MPN: 2519113-1, CH315

Pricing and Lead Time Quote

Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-163-2071 circuit breaker
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925001632071


Privacy | Terms

AS9120B:2015 ISO 9001 Audited and Certified

FAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.

We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.

NSN 5925-00-163-2071 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.

Repairability and Datasheet

NSN 5925-00-163-2071 can be offered in repaired, serviceable, overhauled, or inspected conditions.
National Stock Number (NSN) 5925-00-163-2071
Categorization Automatic circuit breakers, for a voltage not exceeding 1,000 v
Repairability Code N

Approximate Weight 0.7lb
Body Style Multipole-multiple actuator type
Body Length Between 3.025 inches and 3.065 inches
Body Width Between 2.193 inches and 2.241 inches
Body Height Between 2.371 inches and 2.433 inches
Case Material Plastic
Center To Center Distance Between Terminals Parallel To Width 0.424 inches
Fragility Factor Moderately rugged
Boss Height 0.188 inches
Pole Quantity 3
Mounting Facility Type And Quantity 6 terminal
Storage Type General purpose warehouse
Special Handling Feature Magnetic
Maximum Continuous Load Current Rating Per Pole 15.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts 240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 10000.0 ac all locations
Circuit Protection Type Overcurrent all locations
Trip Release Method Thermal-magnetic all locations
Trip Release Characteristic Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 125.0 all locations
Reset Method Manual
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 3 toggle
Actuator Function Trip-reset
Actuator Position Designation At each pole
External Actuator Linkage Arrangement One, two, and three linked
Inclosure Protection Type For Which Designed General purpose
Trip Release Ambient Tempurature Rating 40.0 degrees celsius all locations
Frequency In Hertz 60.0 all locations
Test Data Document 81348-w-c-375/07 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity 6 clip
Specification Data 81348-w-c-375/07-001 government specification

Part Numbers

Part Number Company RNAAC (Repair Depot)
2519113-1 NAVAL AIR SYSTEMS COMMAND MANAGED KE - NAVAL ICP
CH315 EATON CORP KE - NAVAL ICP