NSN 5925-00-159-1517 Repair Services

Circuit Breaker Overhaul, Repair, and Maintenance

MPN: L6193782G22-400, 6193782G22-400

Pricing and Lead Time Quote

Submit this form and receive an overhaul/repair pricing and lead time quote for NSN 5925-00-159-1517 circuit breaker
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925001591517


Privacy | Terms

AS9120B:2015 ISO 9001 Audited and Certified

FAA and EASA Part 145 Certified Repair Stations Ensuring the highest standards of quality and compliance for our clients' needs.

We specialize in the repair and refurbishment of nsn components. From mechanical assemblies to rotor blades, our comprehensive capabilities cover a wide range of NSN parts, providing cost effective solutions to extend the operational life of vital equipment.

NSN 5925-00-159-1517 has been designated as a repairable item and has been included in our capabilities catalog. If you require overhaul or repair services use the form on this page to send us your information. We will provide you with a lead time and price quote.

Repairability and Datasheet

NSN 5925-00-159-1517 can be offered in repaired, serviceable, overhauled, or inspected conditions.
National Stock Number (NSN) 5925-00-159-1517
Categorization Automatic circuit breakers, for a voltage not exceeding 1,000 v
Repairability Code H

If condemned or uneconomically repairable, then dispose at intermediate level.

Approximate Weight 35.3lb
Body Style Rectangular dimensional envelope
Overall Length 22.000 inches
Overall Height 8.375 inches
Overall Width 8.250 inches
Case Material Plastic
Unthreaded Mounting Hole Diameter 0.406 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length 19.875 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width 2.750 inches
Pole Quantity 2
Arc Quenching Method Deion
Mounting Facility Type And Quantity 4 unthreaded hole
Maximum Continuous Load Current Rating Per Pole 400.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 20000.0 dc all locations
Circuit Protection Type Overcurrent all locations
Trip Release Method Magnetic all locations
Trip Release Characteristic Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 700.0 all locations
Reset Method Manual
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 1 toggle
Actuator Function Reset
Special Features Includes terminal hardware to modify breaker for front and/or back connected
Terminal Type And Quantity 4 pin

Part Numbers

Part Number Company RNAAC (Repair Depot)
L6193782G22-400 GENERAL ELECTRIC COMPANY XX -
6193782G22-400 GENERAL ELECTRIC COMPANY XX -